The SHERPA CLT connector is a coupling element for angle joints, t-joints and longitudinal joints, wall to ceiling connections, as
well as ceiling joints.
Optimised for three-layer and five-layer cross-laminated timber elements, the SHERPA CLT connector can be mounted flush in
solid wood or glulam already in the preinstallation phase, enabling ready-for-installation delivery to the construction site.
The CLT connector must be milled flush into cross laminated timber or glulam. The load capacity according to ETA can only be
guaranteed when using SHERPA special screws.
DOWNLOAD ETA assessment Geomertry
Dimensions | 18 x 40 x 110 mm |
Connecting material | 8 Stk. 8,0 x 100 / 120 / 140 mm 2 Stk. 6,5 x 65 mm |
Technical Data
Interlayer ≤ 12 mm | Compriband ≤ 2 mm |
|
Normal forces | Carrying capability | R1,k | 18,80 2) | kN |
Stiffness | Kser | 9.750 | N/mm |
Shear force on the surface | Carrying capability | R2,k | 10,00 2) | kN |
Stiffness | Kser | 3.300 | N/mm |
Shear force from the surface (positive)
| Carrying capability | R3,k·(+) | 16,00 2) | 16,50 2) | kN |
Stiffness | Kser | 3.600 | N/mm |
Shear force from the surface (negative)
| Carrying capability | R3,k·(-) | 5,30 | 7,00 | kN |
Stiffness | Kser | 870 | 1.000 | N/mm |
1) ETA 18/0083
2) screw l = 120 mm: ns = 1,22
screw l = 140 mm : ns = 1,44
R‘k = ns ∙ Rk
A
material thickness: 80 bis 160 mm;
> 120 mm: flush milling or install both-sided
B
edge distance: min. 250 mm
C
min. 100 mm
D
Interlayer (e.g. Regufoam): max. 12 mm
Compression hardness: min. 0,2 N/mm²
Static elasticity modulus: min. 1,0 N/mm²
Installation Instructions
- Milling: 18 mm into solid wood or glulam
- Max. distance between the CLT connectors: emax = 2 m
- 2 pcs. special screws 6.5 x 65
- 4 pcs. special screws 8.0 x 100 / 120 / 140 (fix to solid wood / glulam)
- 4 pcs. special screws 8.0 x 100 / 120 / 140 (mount on the second element)
Recommended Screw Torque
SHERPA Special Screws
6,5 x 65 mm
MT = 2,5 Nm
8,0 x 100 mm
MT = 5,0 Nm
Min.: screw head must be in contact with counter sink